ProLaser III
Kustom Signals, Inc.
ProLaser III is IACP approved
Introduced in 1998
OPERATION
CONTROLS
DISPLAYS / INDICATORS
Target Speed
5 to 200 mph (8 to 321 kmh)
displays plus (+) in front of speed for approaching targets
displays minus (-) in front of speed for receding targets
accuracy: +/- 1 mph (+/- 2 kmh)
Target Range
10 to +4,000 feet (3 to +1330 meters)
accuracy: +/- 0.5 feet (+/-0.2 meters)
resolution: 0.1 feet (0.1 meters)
Alpha Messages: (error messages)
LV Alert -- battery approaching minimum voltage
LV Warnimg -- battery low (unit does not function)
Error -- internal problem (unit does not function)
SPECIFICATIONS
The unit is programmable, some specifications and features, such as speed/range in English or metric units (mph/ft or kmh/m) are a function of software version installed. Some software versions display range (instead of speed) on HUD.
Sample Time 0.3 seconds (300 ms)
Display Update 3 to 4 times per second
Speed Range on-coming and/or going traffic
5 to 200 mph (8 to 321 kmh)
Speed Accuracy +/-1 mph (+/- 2 kmh)
Range 10 to +4000 ft (3 to +1330 m)
Range Accuracy +/-0.5 ft (0.2 m)
Range Resolution 0.1 ft (0.1 m)
Antenna separate transmit and receive apertures
Beamwidth 3 mrad (0.17 degrees)
Supply Voltage
External 10.8 to 16.5 Vdc (0.75 A max)
Internal Removable, rechargeable 9.6 Vdc nom., NiMH battery pack
environmental -22 to 140 degrees Fahrenheit
(-30 to 60 degrees Celsius)
0 to 95 percent relative humidity (non-condensing)
storage temperature -40 to 176 degrees Fahrenheit
(-40 to 80 degrees Celsius)
PHYSICAL height 10.25 in (26.04 cm) includes handle
width 4.25 in (10.8 cm)
length 7.4 in (18.8 cm)
WEIGHT 3.25 lb ( 1.9 kg)
Data Output RS-232 serial port
for PC, still or video camera
data includes speed, direction, range, error messages